All catalog part numbers are for devices with clockwise rotation, however, counter-clockwise rotation is available by request. Encapsulation is available on some designs for high peak power and high altitude capability. Contact our Customer Service Department for special performance and unique mechanical configurations. We have many other designs not listed here on our website as we develop new designs on a frequent basis.

F = Female Connector M = Male Connector
* Case Temperature Not To Exceed Operating Temperature
Frequency Range (GHz) | Insertion Loss (Max) (-dB) | VSWR (Max) | Operating * Temperature oC | Connector # Configuration | Power Rating (Watts) | Dimensions (in x in x in) | Part Number | Outline Drawing | Links | |
---|---|---|---|---|---|---|---|---|---|---|
0.470-0.518 | 0.30 | 1.20 | 0 to +65 | DIN | FFF | 700 | 2.75 x 2.94 x 1.26 | 994-038072-021 | C04 | /wp-content/uploads/2020/12/C04.pdf |
0.470-0.548 | 0.30 | 1.20 | 0 to +65 | N-Type | FFF | 700 | 2.75 x 2.94 x 1.26 | 994-038072-025 | C05 | /wp-content/uploads/2020/12/C05.pdf |
0.487-0.573 | 0.35 | 1.25 | 0 to +65 | N-Type | FFF | 700 | 2.75 x 2.94 x 1.26 | 995-487573-901 | C05 | /wp-content/uploads/2020/12/C05.pdf |
0.518-0.596 | 0.30 | 1.20 | 0 to +65 | DIN | FFF | 700 | 2.75 x 2.94 x 1.26 | 994-038072-022 | C04 | /wp-content/uploads/2020/12/C04.pdf |
0.542-0.656 | 0.30 | 1.20 | 0 to +65 | N-Type | FFF | 700 | 2.75 x 2.94 x 1.26 | 994-038072-026 | C05 | /wp-content/uploads/2020/12/C05.pdf |
0.596-0.704 | 0.30 | 1.20 | 0 to +65 | DIN | FFF | 700 | 2.75 x 2.94 x 1.26 | 994-038072-023 | C04 | /wp-content/uploads/2020/12/C04.pdf |
0.650-0.806 | 0.30 | 1.20 | 0 to +65 | N-Type | FFF | 700 | 2.75 x 2.94 x 1.26 | 994-038072-027 | C05 | /wp-content/uploads/2020/12/C05.pdf |
0.701-0.806 | 0.30 | 1.20 | 0 to +65 | DIN | FFF | 700 | 2.75 x 2.94 x 1.26 | 994-038072-024 | C04 | /wp-content/uploads/2020/12/C04.pdf |
0.806-0.860 | 0.30 | 1.20 | 0 to +65 | N-Type | FFF | 700 | 2.75 x 2.94 x 1.26 | 994-038072-028 | C05 | /wp-content/uploads/2020/12/C05.pdf |